Accuracy of Left Ventricular Ejection Fraction Assessment by Noncardiologists E-Point Septal Separation and Teichholz Methods: Simulation-Based Pre-Post Training Study.
Researchers
Thanat Tangpaisarn, Nattapat Serewiwattana, Praew Kotruchin, Patpitchaya Siritanont, Noor Hafizah Abdul Salim, Pariwat Phungoen
Abstract
Point-of-care ultrasound (POCUS) enables rapid bedside estimation of left ventricular ejection fraction (LVEF) in the emergency department. Among quantitative methods, E-point septal separation (EPSS) and Teichholz-derived calculations are commonly used; however, their comparative accuracy when performed by noncardiologist clinicians remains unclear. This study aimed to compare the accuracy and efficiency of EPSS and Teichholz-based methods for LVEF assessment by emergency department physicians, using the Simpson biplane method as the reference standard. We conducted a prospective pre-post interventional study using standardized patients (SPs) at a university simulation training unit (March 2025). Following prerecorded lectures and demonstration videos, emergency department physicians (n=26) measured LVEF using three bedside methods-EPSS, Teichholz long-axis, and Teichholz short-axis-before and after a focused hands-on training session including supervised image acquisition and guided LVEF measurement. Five SPs with cardiologist-confirmed LVEF values ranging from 16% to 73% were used across the study assessments. The primary outcome was the absolute difference between participant-measured and reference LVEF. Secondary outcomes included time-to-completion and participant-reported confidence for each method. Before training, EPSS demonstrated a significantly lower absolute error (median 5 percentage points, IQR 3-13) compared with Teichholz long-axis (17 percentage points, IQR 9-27) and Teichholz short-axis (13 percentage points, IQR 4-24) methods (P=.009). EPSS also required less time (median 73 seconds, IQR 53-121) than Teichholz long-axis (150 seconds, IQR 103-200) and Teichholz short-axis (100 seconds, IQR 67-184) (P=.02). After training, no statistically significant difference in absolute LVEF error was detected among methods in the preserved-LVEF assessment (P=.93). In the posttraining reduced-LVEF assessment, no statistically significant difference in absolute LVEF error was detected among methods in the SP with an LVEF of 48% (P=.48). In contrast, in the single SP with an LVEF of 16%, absolute LVEF error differed significantly among methods (P=.008), with greater error for EPSS (median 30.5 percentage points) than for Teichholz long-axis (11 percentage points) and Teichholz short-axis (8 percentage points). EPSS remained the fastest technique in preserved (62 seconds; P<.001) and reduced LVEF cases (79 seconds; P<.001). Confidence scores improved across all methods, with EPSS demonstrating the highest median posttraining confidence (P=.01). Greater variability in EPSS measurements was observed in reduced LVEF, with a mean bias of -16 (SD 23) percentage points and wide 95% limits of agreement from -61.1 to 29.1. Following focused ultrasound training, no statistically significant difference in absolute LVEF error was detected among methods in the preserved-LVEF assessment or in the SP with an LVEF of 48%. However, EPSS demonstrated greater error than both Teichholz methods in the single SP with an LVEF of 16%, a case-specific finding that should be considered hypothesis-generating. EPSS required less time to perform and was associated with higher learner confidence. Thai Clinical Trials Registry TCTR20250123008; https://tinyurl.com/3kphcru3.Source: PubMed (PMID: 43097718)View Original on PubMed