•स्क्रिनमा देखिने चुरोट: सुर्तीजन्य हानि न्यूनीकरण नीतिमा दक्षिण एसियाले अझै के छुटाइरहेको छ•नेपालमा पिसाब नलीको संक्रमण र एन्टिबायोटिक प्रतिरोधको बढ्दो संकट•Frontline Perspectives on Nursing Leadership in Nepal•Protecting the Smallest Lungs from the Hidden Grip of RSV in Kathmandu•The Heavy Burden of Bullying on Student Wellbeing in Nepal•The Emerging Landscape of Thyroid Health in Central Nepal•How a Recent Western Nepal Study is Redefining Anemia Diagnosis•How H. Pylori is Impacting the Health of Karnali’s High-Altitude Communities•Sweet Poison, Bitter Reality: The Unseen Diabetes Epidemic Among Nepal’s Youth•How Missing Checklists and Protocols are Costing Lives in Nepal’s ERs•स्क्रिनमा देखिने चुरोट: सुर्तीजन्य हानि न्यूनीकरण नीतिमा दक्षिण एसियाले अझै के छुटाइरहेको छ•नेपालमा पिसाब नलीको संक्रमण र एन्टिबायोटिक प्रतिरोधको बढ्दो संकट•Frontline Perspectives on Nursing Leadership in Nepal•Protecting the Smallest Lungs from the Hidden Grip of RSV in Kathmandu•The Heavy Burden of Bullying on Student Wellbeing in Nepal•The Emerging Landscape of Thyroid Health in Central Nepal•How a Recent Western Nepal Study is Redefining Anemia Diagnosis•How H. Pylori is Impacting the Health of Karnali’s High-Altitude Communities•Sweet Poison, Bitter Reality: The Unseen Diabetes Epidemic Among Nepal’s Youth•How Missing Checklists and Protocols are Costing Lives in Nepal’s ERs

Long-Term Safety and Procedural Performance of an Interatrial Shunt for Heart Failure According to Ejection Fraction.

Researchers

Josep Rodés-Cabau, Gregg W Stone, Saibal Kar, Stefan Verheye, Ariel Roguin, Jeroen Bax, Antoni Bayes-Genis, Julio Nunez, Jeremiah Depta, Michal Laufer-Perl, Gil Moravsky, Alicia Romero, Edgard Prihadi, Eugene S Chung, Matthew J Price, Michael Chenier, Dimitry Schewel, Sachin Kumar, Stephan Kische, Kunjan Bhatt, Kevin S Shah, Daniel J Donovan, Suzanne Hendrix, Patrick O'Keefe, William T Abraham, Michael R Zile, Stefan D Anker, Neal L Eigler, JoAnn Lindenfeld

Abstract

Long-term device durability and phenotype-specific safety outcomes after interatrial shunting require further characterization. This study aimed to evaluate the procedural success, device durability, and heart failure (HF) phenotype-specific safety outcomes of an interatrial shunt in the RELIEVE-HF trial. Randomized patients were assigned 1:1 to shunt or sham control with prespecified stratification by left ventricular ejection fraction (LVEF) into heart failure with reduced ejection fraction (HFrEF) (LVEF ≤40%) and heart failure with preserved ejection fraction (HFpEF) (LVEF >40%). Procedural performance, device durability, serious adverse events (SAEs), major adverse cardiovascular or neurological events (MACNE), major bleeding, and renal outcomes were assessed through 2 years. Among 605 enrolled patients (508 randomized; 97 roll-in), shunt implantation was attempted in 370 and was successful in 369 (99.7%). Among implanted patients with follow-up (n = 348), no device- or procedure-related MACNE occurred through 2 years (0%; 95% CI: 0%-0.9%), and shunt patency was 99.4% (95% CI: 97.9%-99.9%). Prespecified LVEF-stratified analyses demonstrated divergent safety profiles. In HFrEF, shunt therapy was not associated with excess all-cause MACNE, major bleeding, or renal decline and was associated with lower SAE burden. In HFpEF, shunt therapy was associated with higher all-cause MACNE, greater SAE burden, increased major bleeding, and greater renal decline. Interatrial shunt implantation was mechanically reliable and durable through 2 years. Safety outcomes differed by HF phenotype, with no evidence of excess clinical safety events in HFrEF but increased adverse events in HFpEF. These findings support phenotype-specific evaluation of interatrial shunt therapy. (REducing Lung congestion symptoms using the v-wavE shunt in adVancEd Heart Failure [RELIEVE-HF]; NCT03499236).
Source: PubMed (PMID: 42886087)View Original on PubMed